Please note this is the control for existing VentSure or DynaTrol vent systems. Actual vent sold separately.
This new vent control allows you to automatically control the operation of the Vent-Sure kiln vent with one of the outputs from the DynaTrol.
Operation
NOTE: These options are set in the "Hidden Menu".
OPTION A (OP A)
Used to control a vent. Output 4 can be programmed to be on or off during each segment of a Vary-Fire program. During an Easy-Fire program, output 4 comes on at the beginning of the firing and turns off after the kiln has cooled to 150 F.
OPTION B (OP B)
Used to control a vent. Output 4 can be programmed to be on or off during each segment of a Vary-Fire program. Output 4 comes on at the beginning of an Easy-Fire program, off at 1450 F, back on after the firing is complete and the kiln has cooled to 1000F and finally off again when the temperature is below 150F.
OPTION C (OP C)
Used to control a vent, an alarm, or other atmospheric control. Output 4 can be programmed to be on or off during each segment of a Vary-Fire program. Output 4 is off during Easy-Fire programs.